Create validations: Unterschied zwischen den Versionen

Aus firesys Hilfe
Zur Navigation springen Zur Suche springen
Keine Bearbeitungszusammenfassung
Keine Bearbeitungszusammenfassung
Zeile 1: Zeile 1:
You can compare two numbers from one Excel document. You can allocate these to a group and display them in the comparison sheet in a clear overview.  
You can compare two numbers from one Excel document. You can allocate these to a group and display them in the comparison sheet in a clear overview.  
<imagemap>Image:EN_Excel_Menüband_Inhalt_Validierungen.jpg|1200px|center
rect 2 85 204 193 [[The_basic_functions_of_firesys]]
rect 211 82 515 192 [[The_account_workbook]]
rect 522 82 612 192 [[The_functions_of_the_master_value_manager]]
rect 614 81 698 191 [[Synchronise_and_detach]]
rect 884 82 1041 184 [[The_validation_basic_functions]]
rect 702 114 879 136 [[Synchronise_and_detach]]
rect 702 140 880 168 [[Insert_transmitter_values]]
rect 705 81 878 110 [[Insert_values_in_Excel]]
rect 1046 83 1181 190 [[An_overview_of_the_rolling_forward_function]]
desc none
</imagemap>


== Create a validation ==
== Create a validation ==

Version vom 30. April 2020, 13:22 Uhr

You can compare two numbers from one Excel document. You can allocate these to a group and display them in the comparison sheet in a clear overview.


<imagemap>Image:EN_Excel_Menüband_Inhalt_Validierungen.jpg|1200px|center rect 2 85 204 193 The_basic_functions_of_firesys rect 211 82 515 192 The_account_workbook rect 522 82 612 192 The_functions_of_the_master_value_manager rect 614 81 698 191 Synchronise_and_detach rect 884 82 1041 184 The_validation_basic_functions rect 702 114 879 136 Synchronise_and_detach rect 702 140 880 168 Insert_transmitter_values rect 705 81 878 110 Insert_values_in_Excel rect 1046 83 1181 190 An_overview_of_the_rolling_forward_function desc none </imagemap>


Create a validation

Selection of validation values

Datei:EN Excel Validierung-Einzel-Validierung.jpg
The work area of the validations

Select a value

Image.Cell.SelectCell.16.png Transfer value from cell: The value from the currently selected Excel cell is transferred as the validation value if it is a numerical value.


Datei:Image.Cell.AccountValue.16.png Select account value: This opens a dialog with which you can transfer an account value from the master value manager as the validation value.


Image.Cell.SelectMasterCell.16.png Select the transmitter value or manual value: this opens a dialog with which you can transfer an existing master value as the validation value.

Options

The underlying data source of the respective validation value is displayed in the “Selection” field. You will be informed if you have not yet selected anything.

Operator

You can define the mathematical operator multiplication or division for your validation value.

Factor

If you have selected an operator, you can select the decimal powers 1,000/1,000,000 or 1,000,000,000 as the factor for calculating your validation of firesys.

Intermediate calculation

The previously configured calculation of the validation value is displayed written out in an intermediate calculation.

Value/result

Here you always see the current calculation of the previously selected validation and the corresponding operator and factor.


Glühbirne neu.png
Good to know

With an individual calculation, you cannot select an identical cell for “Value 1” and “Value 2”.


Operator/factor

The operator/factor enables values of different units to be validated.

The division or multiplication with the factor thousand, millions and billions is available for selection. To improve transparency, the intermediate calculation is also displayed in the dialogue.

Absolute values

Create validations without taking the sign of the selected values into account.

Additional information

Supplement your validation with additional valuable information:

Group

Validations in firesys must always be assigned to a group. The groups serve to assign the various validations precisely and are the central sorting key on the validation worksheet. You can add new groups or edit and delete existing ones at any time.


Glühbirne neu.png
Good to know

When you create or edit a validation, if you enter and confirm a group name that is already being used, both validation groups can be combined into a group. However, this step cannot be reversed.

Description

Here you can provide a description containing explanatory, additional information about the validation.


Glühbirne neu.png
Good to know

Starting from the selected cell, firesys automatically searches for a description and proposes this in the corresponding field.


Comment

You can add a comment on the current validation here.

Search for terms

Here you can search all worksheets for a term with the following options:

Image.Cell.MatchAll.16.png Compare entire content of cells: The option “Compare entire content of cells” enables you to limit the search further. Example: When searching for the term “EBITDA”, firesys finds all cells in which the term “EBITDA” is used. The term “EBITDA” + the option (“Compare entire content of cells”) only finds cells containing exclusively “EBITDA”.

Image-Common-ArrowLeft.png Previous hit: Use the arrows to start the search and navigate through the individual hits and to the previous hit.

Image-Common-ArrowRight.png Next hit: Use the arrows to start the search and navigate through the individual hits and to the next hit.

Case study: create a validation


Die Erklärung der einzelnen Schritte im Detail

So fügen Sie eine neue Validierung in Excel ein:

  1. Klicken Sie auf den Knopf „Validierung erstellen“ im Menüband „*Inhalt“ in der Gruppe „Validierungen“.
    → Ein Auswahldialog öffnet sich, der Ihnen die verschiedenen Validierungstypen anzeigt.

  2. Wählen Sie hier die Funktion „Einzel-Validierung“.
    → Ihr Excel-Arbeitsblatt wird um den Validierungs-Arbeitsbereich erweitert.

  3. Wählen Sie mit dem Mauszeiger die Zelle, für die die Validierung erstellt werden soll, aus und drücken Sie im Bereich „Wert 1 auswählen“ auf den Knopf „Wert aus Zelle übernehmen“.

  4. Wählen Sie nun die Zelle in Ihrer Excel-Arbeitsmappe aus, die den zweiten Wert der Validierung enthält und drücken Sie im Bereich „Wert 2 auswählen“ auf den Knopf „Wert aus Zelle übernehmen“.

  5. Bestätigen Sie die Eingabe mit einem Klick auf „Ok“.
    → Ein Informationsdialog bestätigt Ihnen die Erstellung der Validierung.

  6. Öffnen Sie mithilfe der Funktion „zum Validierungsblatt wechseln“ das Validierungsblatt.
    → Ihre Validierung wird angezeigt.

See also

Navigation hoch.svg An overview of the validation functions
Navigation rechts.svg Create multiple validations
Navigation rechts.svg Create auto-validations
Navigation rechts.svg Edit validation
Navigation rechts.svg Delete validation
Navigation rechts.svg Approve deviations

Further contents

firesys website
Customer area
YouTube